IWA-IP10 Veterinary Infusion Pump (1200 ml/h, 10h Battery)

Contact for price

Vertical-design veterinary infusion pump with 1.0–1200 ml/h flow rate (±5% post-calibration), 3.2″ color LCD, numeric keypad, 3000 mAh lithium battery (>10 h backup) and 10-level adjustable occlusion / air-bubble detection with pressure-release function.

SKU: IWA-IP10 Category:

Vertical-design veterinary infusion pump with 1.0–1200 ml/h flow, 3000 mAh lithium battery, 10-level occlusion + bubble detection and pressure-release function.

Hero Media

IWA-IP10 veterinary infusion pump in clinical use - two veterinarians examining feline patient with pump on stainless treatment table

Product Overview

The IWA-IP10 is a classic vertical-design veterinary infusion pump built for accurate, repeatable IV fluid delivery in canine, feline and exotic-pet practice.

A 3.2″ high-brightness color LCD, full numeric keypad and dual-CPU control deliver a ±5% flow accuracy (after calibration) across the full 1.0–1200 ml/h range. A 3000 mAh rechargeable lithium battery provides more than 10 hours of cordless runtime at 25 ml/h, with 10-level adjustable occlusion-pressure detection (40–130 kPa) and ultrasonic air-bubble detection (≥50 μL) for safer overnight and unattended infusion.

Key Features

  • Wide 1.0–1200 ml/h flow range — 0.1 ml/h step (1.0–99.9 ml/h) and 1 ml/h step (100–1200 ml/h)
  • ±5% flow accuracy after calibration — safer for low-volume neonatal and exotic patients
  • Three infusion modes — Volume mode, Time mode, Drug mode
  • 3.2″ bright color LCD — readable at a glance from across the recovery room
  • Full numeric keypad — faster, less error-prone entry vs scroll-wheel pumps
  • 3000 mAh Li-ion battery — >10 h runtime at 25 ml/h, real-time remaining-battery display
  • 10-level adjustable occlusion-pressure detection (40–130 kPa) with dynamic pressure display
  • Ultrasonic air-bubble detection — sensitivity 50–300 μL, 10 levels adjustable
  • Occlusion-pressure release function — automatic depressurise + restart after blockage cleared
  • BOLUS function with adjustable flow rate for rapid loading dose
  • KVO (Keep Vein Open) 1.0–5.0 ml/h, adjustable
  • Purge mode 600 ml/h with displayed purge volume
  • Night mode — auto-dim screen 5 min after standby
  • Open IV-set system — accepts standard 10/15/20/60 d/mL single-use sets (3.4–4.5 mm diameter) after calibration
  • Motor anti-reverse function with real-time monitoring
  • 15+ audio-visual alarms covering air bubble, occlusion, door open, battery, motor, sensor and parameter errors
  • Self-test before startup and continuously during infusion
  • Universal-input 100–240 V AC, 50/60 Hz, ≤ 25 VA — global mains compatible
  • Type CF / Class I / IPX3 classification
  • Compact 145 × 150 × 200 mm, 1.7 kg — pole-mount or table-top

Technical Specifications

Model IWA-IP10 (HF-710C platform)
Infusion Mode Volume Mode, Time Mode, Drug Mode
Rate Unit ml/h, volume/time, d/min
IV Sets Standard single-use IV sets (10 / 15 / 20 / 60 d/mL, diameter 3.4–4.5 mm)
Flow Rate 1.0–1200 ml/h
Increment 1.0–99.9 ml/h in 0.1 ml/h step; 100–1200 ml/h in 1 ml/h step
Flow Accuracy ≤ ±5% (after calibration)
VTBI (Volume To Be Infused) 0.1–9999.9 ml
Total Volume 0.0–9999.9 ml
Time Range 1 min–99 h 00 min
Purge Rate 600 ml/h, displayed purge volume
KVO 1.0–5.0 ml/h, adjustable
BOLUS Available, flow rate adjustable
Night Mode Screen auto-dim 5 min after standby
Occlusion Pressure Detector 40–130 kPa, 10 levels adjustable, dynamic pressure display
Occlusion Release Function Available (auto-depressurise + restart)
Air Bubble Detector Ultrasonic, ≥ 50 μL; single-bubble volume 50–300 μL, 10 levels adjustable
Bolus Volume Levels 8 levels adjustable
Motor Anti-reverse Active anti-reverse + real-time monitoring
IV-Set Management Open system; accepts different IV brands after calibration
Self-Test Pre-startup + continuous during infusion
Alarm Conditions Air bubble, occlusion, door open, infusion finish, standby expired, battery low/empty/disengaged, AC disengaged, motor / pump / air-sensor / parameter / system error, IV not calibrated
Screen 3.2″ high-brightness color LCD
Keypad Full numeric
Power Supply AC 100–240 V, 50/60 Hz, ≤ 25 VA
Battery Rechargeable Li-ion DC 11.1 V, 3000 mAh; ≥ 10 h @ 25 ml/h, with remaining-battery display
Operating Environment +5 °C to +40 °C, 20%–90% RH, 70–106 kPa
Transport / Storage −20 °C to +55 °C, 10%–95% RH, 70–106 kPa
Classification Type CF, Class I, IPX3
Dimensions 145 × 150 × 200 mm
Weight 1.7 kg
Warranty 1 year, hardware & software

Visual Evidence

IWA-IP10 veterinary infusion pump product view - 3.2 inch color LCD, numeric keypad, BOLUS/START/STOP buttons, top carrying handle and integrated door for IV set loading
Front view: 3.2″ color LCD shows VTBI / TIME / flow rate; numeric keypad and dedicated BOLUS / START / STOP buttons; top carrying handle and integrated door for IV-set loading.
IWA-IP10 full technical specification table - infusion mode, flow rate, VTBI, occlusion pressure detector, air bubble detector, battery, dimensions
Full technical specification — complete table including infusion modes, flow / VTBI ranges, occlusion / bubble detection, alarms and environmental ratings.

Clinical Applications

  • Routine IV fluid therapy in canine and feline patients
  • Critical-care and ICU continuous infusion with KVO and accurate dosing
  • Post-surgical fluid maintenance and antibiotic delivery
  • Overnight unattended infusion with battery backup and full alarm suite
  • Exotic and neonatal patients requiring sub-1 ml/h precision
  • Ambulatory clinic and house-call work — cordless 10+ h battery operation

Workflow & Installation Notes

  • Pole-mountable or table-top — 1.7 kg chassis fits standard veterinary IV poles
  • Open IV-set system — staff calibrate the first new-brand set, then save the profile for repeat use
  • Daily pre-startup self-test runs in under 30 seconds; continuous self-monitoring during every infusion
  • Night mode dims the screen 5 min after standby — reduces light disturbance in recovery wards
  • Occlusion release auto-depressurises after blockage is cleared, then resumes infusion — reduces alarm fatigue and unnecessary line replacement

Package Contents

  • 1 × IWA-IP10 veterinary infusion pump
  • 1 × AC power cord (100–240 V)
  • 1 × Pole-mount clamp
  • 1 × User manual
  • 1 × Warranty certificate
  • Optional: standard veterinary IV sets (10 / 15 / 20 / 60 d/mL)

Why Choose IWA-IP10

  • Safety-first design: dual-CPU control, ultrasonic bubble detection, 10-level occlusion + bubble settings and motor anti-reverse give multiple independent safeguards on every infusion.
  • True 10+ hour battery: 3000 mAh lithium pack runs > 10 h at 25 ml/h — the pump keeps delivering through power outages and inter-room transport.
  • Occlusion release function: auto-depressurise + restart after a blockage clears — cuts alarm fatigue and avoids unnecessary IV-set replacement.
  • Operator-friendly UI: numeric keypad + big 3.2″ color LCD beats scroll-wheel pumps for entry speed and night-shift readability.
  • Open-system IV compatibility: accepts any standard veterinary IV brand after a one-time calibration — no proprietary consumable lock-in.

Warranty & Support

1-year manufacturer warranty on hardware and software. Battery covered as a consumable under standard 6-month terms. Iwamed provides remote diagnostics, calibration support and spare-parts logistics through the local distributor.

Frequently Asked Questions

Can the IWA-IP10 use any IV set?
Yes — it is an open-system pump and accepts standard veterinary IV sets in 10 / 15 / 20 / 60 d/mL with tube diameter 3.4–4.5 mm. The first use of a new brand requires a one-time calibration, which is saved to the pump.
What happens during a power outage?
The 3000 mAh built-in lithium battery automatically takes over and provides > 10 h of cordless operation at 25 ml/h. The display shows remaining battery in real time, and the pump alarms in advance when the battery is low.
What is “occlusion pressure release” and why does it matter?
When a line becomes blocked, pressure builds up upstream of the obstruction. Many pumps simply alarm and stop, leaving the operator to manually relieve pressure. The IWA-IP10 automatically depressurises and resumes infusion once the blockage clears — reducing alarm fatigue and the need to replace IV sets.
Is the IWA-IP10 suitable for very small patients?
Yes — the 0.1 ml/h step at low flow rates and 50 μL ultrasonic bubble detection support neonatal canine, feline and exotic patients.
How is it cleaned between cases?
Wipe-down with standard veterinary disinfectant; the IPX3 splash-resistant chassis tolerates routine clinic cleaning protocols. Do not immerse the pump.
Dimensions 20 × 15 × 14.5 in

Reviews

There are no reviews yet.

Be the first to review “IWA-IP10 Veterinary Infusion Pump (1200 ml/h, 10h Battery)”