Low-temperature ethylene oxide (EO) gas sterilizer for heat- and moisture-sensitive instruments — 30–60 °C operation, 304 stainless steel chamber in four capacities (80 / 120 / 220 / 300 L), 5″ colour LCD touch panel, USB data export, integrated mini printer, parametric release.
Product Overview

IWA-VPSS02 is a low-temperature ethylene oxide (eo) gas sterilizer for heat- and moisture-sensitive instruments — 30–60 °c operation, 304 stainless steel chamber in four capacities (80 / 120 / 220 / 300 l), 5″ colour lcd touch panel, usb data export, integrated mini printer, parametric release. Suited for sterilization of heat- and moisture-sensitive veterinary instruments (flexible endoscopes, fibre optics, electronics), sterilization of polymer-coated and plastic instruments incompatible with steam.
Key Features
- Low-temperature EO sterilization (30–60 °C) — suited to heat- and moisture-sensitive items that cannot tolerate steam autoclaving.
- Excellent penetration with no lumen restrictions — gas-phase sterilant reaches narrow channels and complex geometries.
- Non-corrosive to materials — compatible with polymers, electronics, optics, and surface coatings.
- Four chamber capacities — 80 L (SQ-H80), 120 L (SQ-H120), 220 L (SQ-H220), 300 L (SQ-H330) — choose at order based on daily throughput.
- 304 stainless steel chamber — corrosion resistance and easy validation cleaning.
- 5″ colour LCD touch panel — process clearly displayed on screen.
- Pre-dosed EO gas cartridges — 48 g / 72 g / 170 g / 240 g cartridges sized per chamber; safe and convenient for the operator.
- Integrated mini printer — hard-copy cycle report at end of every run.
- USB data export — cycle reports automatically saved to USB drive.
- Parametric release supported — products may be released immediately after validated process completion for faster turn-around.
- Relatively low capital equipment cost for low-temperature sterilization capability.
Product Gallery





Technical Specifications
| Model lineup | SQ-H80 / SQ-H120 / SQ-H220 / SQ-H330 |
| Chamber volume | 80 L / 120 L / 220 L / 300 L |
| Chamber size SQ-H80 | 585 × 275 × 422 mm |
| Chamber size SQ-H120 | 585 × 375 × 472 mm |
| Chamber size SQ-H220 | 705 × 505 × 552 mm |
| Chamber size SQ-H330 | 760 × 545 × 712 mm |
| Machine size SQ-H80 | 795 × 615 × 1140 mm |
| Machine size SQ-H120 | 795 × 615 × 1140 mm |
| Machine size SQ-H220 | 968 × 800 × 1240 mm |
| Machine size SQ-H330 | 968 × 800 × 1340 mm |
| Net weight | 110 kg / 147 kg / 207 kg / 227 kg |
| Power | 2.6 kVA / 3.0 kVA / 3.3 kVA / 3.6 kVA |
| Voltage | AC 220 V (all models) |
| Chamber material | 304 stainless steel |
| Working pressure | -60 kPa |
| Cycle time | 5–8 hours |
| Working temperature | 30–60 °C |
| Humidity range | 45–85 % RH |
| Display | 5″ colour LCD touch panel |
| Data export | USB |
| Printer | Mini printer (integrated) |
| Gas cartridge | 48 g (H80) / 72 g (H120) / 170 g (H220) / 240 g (H330) |
| Shelves (trays) | 1 (H80, H120) / 2 (H220, H330) |
Clinical Applications
- Sterilization of heat- and moisture-sensitive veterinary instruments (flexible endoscopes, fibre optics, electronics)
- Sterilization of polymer-coated and plastic instruments incompatible with steam
- Reprocessing of complex lumens (catheters, biopsy channels) where steam may not fully penetrate
- Sterile reprocessing in busy mixed-practice and specialty veterinary hospitals
- Reprocessing of imaging probes and ultrasound transducers (per manufacturer compatibility)
Workflow
Load the chamber with bagged instruments in EO-compatible breathable packaging. Insert the pre-dosed EO gas cartridge sized for the chamber. Confirm cycle parameters on the 5″ colour LCD touch panel — the system runs gas diffusion at 30–60 °C, -60 kPa working pressure, 45–85 % RH for the validated cycle duration (5–8 hours total). On completion, the mini printer outputs the cycle report and the same data exports to USB. Parametric release allows immediate use of the load after a validated process completes. Aerate per local regulation before patient use.
Package Contents
- 1 × IWA-VPSS02 EO sterilizer (capacity selected at order: 80 / 120 / 220 / 300 L)
- 1 or 2 × Internal wire-mesh shelf (per capacity)
- 1 × Pre-dosed EO gas cartridge (sized to capacity, 48 / 72 / 170 / 240 g)
- 1 × Integrated mini printer (built-in)
- 1 × Power cord (AC 220 V)
- 1 × USB drive for cycle-report export
- 1 × User manual
- 1 × Quality certificate
Downloads
Why Choose IWA-VPSS02
- Workflow efficiency — pre-dosed gas cartridges + parametric release + USB report export streamline daily reprocessing of complex instruments.
- Clinical accuracy — gas-phase sterilant penetrates lumens and porous geometries that steam cycles cannot guarantee.
- Practice economics — four capacities right-size the equipment to the practice; lowest cost route to low-temperature sterilization vs. plasma or vaporised hydrogen peroxide.
Warranty & Support
Manufacturer warranty per supply agreement. Spare parts and authorised in-region service available through IWA Medical / LumaVet.













Reviews
There are no reviews yet.